Webserver guide

Battery Emulator has a built-in web interface. With it you can check the battery status, change the configuration, update the software over-the-air, check events, monitor the cell voltages and much more. It makes commissioning a new system easy, and it is the preferred way to monitor a newly set up battery.

IMPORTANT

Never expose Battery Emulator to the internet without a firewall. Never ever port forward it to be accessible directly on a WAN port! Use a private VPN to the site to access its web interface over an encrypted channel. The web interface uses plain HTTP, so nothing you send to it is encrypted. Without password protection the board refuses requests from outside the local network, but treat that only as a safety net.

Connecting to the web interface~

The web interface is reachable on port 80 of the board, either through your home Wi-Fi network or through the Wi-Fi access point the board broadcasts itself.

Minimum browser requirements:

Browser Minimum version required
Chrome / Chrome Android / Android WebView 80 (2020)
Edge 80 (2020)
Firefox / Firefox Android 74 / 79 (2020)
Safari desktop / iOS 14 / 14 (2020)
Samsung Internet 13.0

A: Through your home network~

To have Battery Emulator accessible in your home network, enter your home Wi-Fi credentials in the Network config section of the Settings page. See the installation steps for how to perform the initial Wi-Fi setup.

NOTE

Only 2.4 GHz networks are compatible, 5 GHz will NOT work! The network must be password protected: the SSID can be at most 32 characters long (the limit of the Wi-Fi standard), and the password must be 8-63 characters long.

When the board boots, it will attempt to connect to the Wi-Fi network you specified. When several access points broadcast the same SSID (mesh or multi-AP networks), it always joins the one with the strongest signal. Your router will give it an IP address (unless you set a static IP), so next up is figuring out what that address is. There are a few options:

  • Connect temporarily to the Battery Emulator's access point, browse to 192.168.4.1, and read out the address it got at the top of the main page (hostname followed by the IP in square brackets)
  • Browse to http://battery-emulator-a1b2.local (with the board's own hostname). This mDNS address works on all boards except the small flash boards, and if your network and computer support mDNS.
  • Check your router. If your home router has a login page (typically 192.168.1.1), you can see the devices connected to your home network there. The board shows up as battery-emulator-a1b2 (or the custom hostname you set) in its DHCP leases table.
  • Connect via USB and read out the serial output with a serial terminal at 115200 baud (if you only see ????? in the terminal, the baud rate is wrong). When the board joins the network it prints the line Got IP address: .... The board only prints to USB when General logging via USB serial is enabled.

Once the address of the board has been determined, open a web browser on a device that is connected to the same home network, and type in the address. This opens the main page of the web interface.

B: Through the access point~

By default, the board broadcasts a Wi-Fi access point (AP) with the SSID battery-emulator-a1b2 (containing the last two bytes of its MAC address). If you set a custom Hostname, the access point takes that name instead. The default password is 123456789. After connecting your laptop/phone to this network, open a web browser and browse to 192.168.4.1.

You have to change the access point password in the Network config to improve cyber-security: while the access point is running with the factory-default password, it is automatically switched off after 5 minutes, raising a corresponding event. It is not switched off while a device is connected to it, and it gets a new 5 minute window after every reboot. If a custom access point password has been set, it stays enabled indefinitely. The default-password access point being limited to a short provisioning window mitigates the attack vector while keeping first-time setup and recovery access fully functional.

If a home network is configured but the board can’t join it after booting (wrong password, network out of range), the access point is brought up automatically as a rescue path, even if it’s disabled in the settings. This lasts for that boot only; the setting itself isn’t changed, and with the default password it will be up for 5 minutes as described above.

If you don't plan to use the access point on a regular basis, disable it with Broadcast Wi-Fi Access Point. Not only will the system be more secure, it will also consume less energy and the board will run 10 degrees cooler, because the radio will not be transmitting continuously. Bonus: less radio interference.

TIP

If you disabled the access point earlier and need to use it again without having access to the home network, you can turn it back on with the BOOT button on the board.

NOTE

Make sure that your home network is not on 192.168.4.x, since this conflicts with the built-in access point.

Pages at a glance~

Page Address How to get there What it is for
Main page / Start page Live status of the system, control buttons
Settings /settings Change Settings All configuration
More battery info /advanced More Battery/Cell Info Battery specific details, DTCs, battery commands
Cellmonitor /cellmonitor Cellmonitor on the More battery info page Cell voltages and balancing
CAN tools /canreplay CAN tools CAN dump and CAN replay
Log /log Log (only when logging to the Webserver or to SD card is enabled) General log
Events /events Events, or Inspect reason next to a FAULT What happened since boot
OTA update /update Perform OTA update Firmware update

Main page~

The main page gives a quick overview of the system in a couple of cards, with buttons to the other pages and functions below them.

mainpage

The title Battery Emulator at the top links to this wiki. On release builds the browser also checks GitHub for a newer release (at most every 6 hours) and shows a New version ... available link under the title when there is one.

System information~

  • The software version (on official release and pull request builds it links to the release or the pull request on GitHub), the hardware it is running on and, if Measure CPU temperature is enabled, the CPU temperature
  • The uptime ("for 2 days, 5 hours, 12 minutes")
  • If Performance profiling on main page is enabled: free heap, flash mode and size, and task timing figures. These are meant for developers.
  • The SSID of the home network, with the signal strength (RSSI) and Wi-Fi channel when connected
  • The hostname and the IP address in square brackets. While ESPNow is running, the board's MAC address is shown after the IP, which is the address to enter in the receiver list of other ESPNow nodes. When not connected to any network, Network state: Disconnected is shown instead.
  • Access Point active and its IP, while the access point is running

Inverter and battery setup~

The configured Inverter protocol, Battery protocol (marked ② or ③ for a double or triple battery setup, and (LFP) for LFP chemistry), the optional current Measurement device (for the QNHCK2-16, a ✓ means its current is the one in use) and the optional Charger protocol.

Battery cards~

The live data of the battery, as transmitted to the inverter: SOC, SOH (Unknown until the battery has reported it), voltage, current, power, total and remaining capacity, the maximum charge and discharge power and current allowed, the lowest and highest cell voltage and the difference between them (Cell delta, shown red if it exceeds what the battery integration considers safe), the minimum and maximum temperature, and finally whether the battery is charging, discharging or idle. Some integrations also show the state of the battery's BMS (Battery BMS status).

With Rescale SOC active, Scaled SOC, Scaled total capacity and Scaled remaining capacity are shown, with the real values in brackets.

The colour of the card shows the state of the system:

Colour Meaning
🟩 Dark green All is well
🟨 Yellow A warning event is active
🟥 Red An error event is active, operation is blocked
🟦 Blue A reboot or firmware update is in progress

When there is a warning or an error, check the Events page to see what went wrong. The status LED of the board follows the same colours.

With a double or triple battery setup, a combined card on top shows the whole installation, which is what the inverter sees, and one card per battery pack below it shows that pack's own data, unscaled, with the power limits its own BMS asked for. The combined card's charge limit can be higher than any single pack's (Parallel headroom tracking). See How the packs become one virtual battery for details.

Next to the Max discharge current and Max charge current you can see what is setting the limit:

image

  • (BMS): the limit requested by the battery
  • (Manual): the Max charge/discharge current set on the Settings page, because it is lower than what the battery allows
  • (Remote): a temporary limit set through MQTT SET_LIMITS

While an equipment stop is active, the limits are shown in red.

Limiting factor display~

The last line of the card shows which component is limiting the charge/discharge:

limit

limit

  • (Inverter limiting): the current flowing is lower than what the system allows, so the inverter is the bottleneck
  • (Settings limiting): the current is capped by the Max charge/discharge current setting
  • (Battery limiting): the current is at the limit the battery allows

If no current is flowing in or out of the battery, the text simply says Battery idle.

System status~

  • System status: OK, STANDBY, INACTIVE, UPDATING or FAULT. Next to a FAULT, an Inspect reason button opens the Events page.
  • Power status: RUNNING, or in red PAUSING, PAUSED or RESUMING (see Pause charge/discharge)
  • Emulator allows contactor closing: ✗ while there is a FAULT
  • Inverter allows contactor closing: whether the inverter permits closing the contactors (for inverter protocols that control the battery contactors)
  • 2ⁿᵈ / 3ʳᵈ battery allowed to join: ✗ (voltage mismatch) while the voltage of the extra pack differs too much from the main battery to connect it in parallel
  • Contactors control: when Battery Emulator drives the contactors itself (contactor control via GPIO), the state of the contactors: OFF (DISCONNECTED), PRECHARGE, ON (or Economized with PWM control), or OFF (FAULT), which needs a reboot to recover from. Otherwise it shows non-exclusive: the contactors are controlled via CAN or other methods, and Battery Emulator has only limited influence over them.

If a charger is configured, an 🟧 orange card shows its state and output values.

Buttons~

  • Pause charge/discharge: after a confirmation, sets the maximum charge and discharge power to zero, preventing any further power flow. It does not open the contactors. The Power status shows PAUSING until the current has dropped below 1.8 A on every battery, then PAUSED. The button changes to Resume charge/discharge. The pause is not remembered across a reboot.
  • Perform OTA update: opens the OTA update page.
  • Change Settings: opens the Settings page.
  • More Battery/Cell Info: opens the More battery info page.
  • CAN tools: opens the CAN tools page.
  • Log: opens the Log page. Only shown when General logging via Webserver or General logging to SD card was enabled when the board booted.
  • Events: opens the Events page.
  • Reboot Emulator: restarts Battery Emulator, after a confirmation. See Reboot.
  • Logout: only shown when password protection is enabled. Afterwards, cancel the browser's login prompt to finish logging out.
  • Open Contactors (red): after a confirmation, activates an equipment stop, exactly as a physical equipment stop button would. It is stored, so it stays active after a reboot. While it is active the button changes to Close Contactors (green), which releases the stop and enables power transfer again.

Reboot~

Reboot Emulator restarts Battery Emulator. This can be useful to get out of a latched error blocking operation (critical cell condition, etc.). The emulator first pauses charging and discharging, and restarts once the current has stopped, after 5 to 10 seconds. The main page shows Waiting for the emulator to restart meanwhile, and reloads itself when the emulator is back.

NOTE

Rebooting the Emulator might open contactors! If you have configured the hardware to control contactors via GPIO (see Automatic Contactor Control), they will absolutely open during a reboot! CAN controlled contactors have undefined behavior during reboot.

NOTE

Rebooting the Emulator might put your inverter in a fault state. Some inverters take the reboot without any issues (Fronius Gen24), but others can properly lock themselves (SMA Tripower), and require a reset on the inverter side to get going again.

Automatic refresh~

The main page refreshes its data from the Emulator every 15 s, without reloading the whole page. Clicking or tapping any of the data cards triggers an instant refresh (the data dims briefly to acknowledge it). The maximum refresh rate allowed is 1 s, but please, don't abuse it. A browser tab in the background does not refresh at all, it catches up as soon as it is shown again.

If a refresh fails, the page keeps the data it shows and retries every 5 seconds. From the second failure in a row the data is dimmed and the reason is displayed, so outdated values never pass for fresh ones:

retry

The page recovers automatically as soon as the connection is reestablished. When it notices that the emulator has restarted in the meantime (a reboot or an OTA update), it reloads itself completely, so it always matches the running firmware.

Settings~

The Settings page holds all the configuration of Battery Emulator. It is made of two parts:

  • The settings form (the cards from Network config to Debug options). Changes made here are stored by the Save button at the bottom of the page, and most of them take effect only after a reboot: after saving, the message Settings saved. Reboot to take the new settings into use. appears at the top and at the bottom of the page, with a Reboot button.
  • The battery limits and actions below the form (the green card, starting with Rescale SOC). These are changed one by one with their Edit or Start buttons, are stored right away and take effect immediately, without a reboot. See Battery limits and actions.

Most fields only appear when they are relevant: options of a specific battery, inverter or component appear when that one is selected, and the details of an option appear once it is ticked. Below the form, a grey card shows the interfaces the running battery, inverter and measurement device use.

When saving, the page checks your input: the browser marks fields with an invalid format, and saving is refused if two batteries are assigned to the same CAN interface (each battery needs a CAN interface of its own, only the Fake battery can share one), or if the web interface passwords don't match.

The Factory reset button at the top of the page erases all stored settings and the Wi-Fi calibration data, and restarts the board. It then comes back up like a newly flashed board: with no home network configured and with its access point running with the default password. The same can be done with the BOOT button.

TIP

Settings are kept across OTA updates, you don't have to configure the system again after updating.

Help texts~

The Settings page contains an embedded help, with short explanations about the configuration items. Click or tap the small ⓘ icon next to an item, where available, to display the information, and again to close it. Links in the help texts point to the wiki pages documenting the item, and open in a new window. When the browser rejects the format of a value on saving, the help of that field opens by itself, showing the format rule. The same ⓘ icons are used on the main page, the CAN tools page and the More battery info page too.

help

The texts are fetched from GitHub by the browser and cached for an hour, so they are always up to date, even with older firmware. Boards with enough flash also carry the texts as they were when the firmware was built, which is used when GitHub cannot be reached (for example when connected only to the board's access point).

NOTE

On the small flash boards (LilyGo T-CAN485, ESP32 DevKit) the help is shown only when the browser has Internet access, or has a copy cached from a previous visit.

Network config~

Setting Description
SSID The name of your home Wi-Fi network, up to 32 characters
Password The password of your home Wi-Fi network, 8-63 characters. The stored password is never shown, leave the field blank to keep it.
Hostname Letters, numbers, _ and -. Leave it blank to use the default battery-emulator-a1b2. It is also the SSID of the access point, the mDNS name and the MQTT topic name. As it is used as the SSID, keep it within 32 characters.
Use static IP address Use fixed addresses instead of the ones given by your router's DHCP server. Ticking it while the board is connected fills in the addresses currently in use, so making the current address permanent is just a matter of saving. Fill in Local IP, Gateway and Subnet mask; leave DNS server blank to use the gateway, which is correct on most home networks. If the addresses are invalid, the board falls back to DHCP.
Broadcast Wi-Fi Access Point Enabled by default. See B: Through the access point.
Access Point password 8-63 characters, leave it blank to keep the current one. Change it from the default 123456789!
Wifi channel 0-14 Force a specific Wi-Fi channel, 0 (default) finds it automatically

Web interface access~

Tick Enable password protection and set a Username (admin by default, up to 32 characters) and a Web interface password (up to 63 characters, entered twice) to require a login for all the pages, including the OTA update page. Saving is refused if the username or the password is missing. The protection takes effect after a reboot, and a Logout button appears on the main page.

The login uses HTTP Basic authentication. This protection level is not particularly robust: the username and the password are only encoded, not encrypted, and they are sent with every request over plain HTTP, so anyone able to watch your network traffic can read them. It is sufficient to prevent non-malicious usage within the internal network on which it operates, but it is no replacement for keeping the device off the internet.

NOTE

If you forget the password, a factory reset with the BOOT button clears it, together with all other settings.

Without password protection~

While password protection is off, the web interface only answers devices on the local network, and only when they reach it by a local name or address. Anything else gets a page saying so (HTTP 403), and the general log shows a warning, at most once a minute, with the address and the name that were refused.

A request counts as local when both of these hold:

Checked Accepted
The address of the connecting device A private address (10.x.x.x, 172.16.x.x-172.31.x.x, 192.168.x.x), a link-local address (169.254.x.x) or an address in the board's own subnet. Never the router (gateway) itself, and never a carrier-grade NAT address (100.64.x.x-100.127.x.x).
The name or address in the browser's address bar The board's own IP address, on the home network or on its access point; its hostname, alone or followed by any domain (battery-emulator-a1b2, battery-emulator-a1b2.local, battery-emulator-a1b2.fritz.box); any name without a dot; or a name ending in .local, .lan, .home, .home.arpa, .internal or .localdomain.

This refuses a port forward whether it is reached by your public IP address or by a dynamic DNS name, also on routers that hand forwarded connections over with their own address. It refuses a few setups inside the home network too:

  • Opening the board through your public address or dynamic DNS name from inside the network. Use its local IP address or hostname instead.
  • A local DNS name under a real domain that does not start with the board's hostname, for example solar.example.com. Use the IP address or the hostname, or turn password protection on.
  • A reverse proxy that passes the original public name on to the board.

WARNING

This is a safety net against exposing the board by accident, not access control. A proxy, tunnel or NAT that rewrites both the address and the name looks local. Turning password protection on lifts the restriction entirely: from then on the login is the only thing between the internet and the board, and it travels over plain HTTP. For remote access this is still not safe enough, use a VPN as described at the top of this page.

Battery config~

image

Select the integration of your battery from the Battery dropdown list, the Battery interface the battery is wired to, and any battery-specific settings that may be required. Each battery has its own page in this wiki with the wiring and the settings it needs.

An interesting type is the Fake battery for testing purposes, which simulates a single, double or triple battery towards the inverter and the integration platforms. Its voltage and SOH are set for each pack on the More battery info page.

Depending on the battery selected, more options appear:

Option Shown for Description
Balancing strategy, Automatic current offset correction, Interlock required Nissan LEAF See Nissan LEAF software configuration. Changing the starting sequence request offers to reset the BMS right away, as the BMS only reads it while starting up.
Digital HVIL (2024+), Right hand drive, Country code, Map region, Chassis type, Pack type Tesla Model 3/Y, Tesla Model S/X See Tesla Model 3/Y
Power limits Daly BMS See Daly BMS configuration
Manual charging power, watt, Manual discharge power, watt Integrations whose battery does not report usable power limits The continuous charge and discharge power allowed. Do not set them too high!
Use estimated SOC Some integrations Use an estimated SOC when the battery does not provide an accurate one
Use estimated charge limits Some integrations Use the manual charge/discharge power when the battery does not report usable limits
Battery max/min design voltage (V), Cell max/min design voltage (mV) BMS type integrations (Orion, SIMPBMS, Daly, RJXZS etc.) and some others The safe voltage range of the whole pack and of a single cell, used as charge target and protection limits
Pylon CAN baudrate (kbps) Pylon HV battery 500 kbps for most batteries, 250 kbps for some
Double battery with 2ⁿᵈ interface, then Triple battery with 3ʳᵈ interface Integrations that support double or triple batteries Run two or three packs in parallel, each on a CAN interface of its own
Parallel headroom tracking Double or triple battery Raises the combined charge limit above the lowest pack limit, to what the packs take together. Off by default. See Parallel headroom tracking

Inverter config~

image

Select the Inverter protocol the Emulator should talk to your inverter with, and the Inverter interface it is wired to. Each supported inverter has its own page in this wiki explaining which protocol to choose.

Depending on the protocol selected, more options appear right below:

Option Shown for Description
Sofar Battery ID (0-15) Sofar Battery ID, for running several packs in parallel. See Sofar
Pylon, send group, 30k offset, invert byteorder, manufacturer name Pylon HV Compatibility options needed by some inverters using this protocol, for example Sofar, Hoymiles or Deye
Deye avoid over/undercharge fix BYD CAN See Deye
Accept reboot command from inverter, Fronius Primo, 450V maxvoltage cap, WatchDog Timeout, Inverter time (UTC) BYD Modbus See Fronius. The last two only display what the inverter has sent.
Reported cell count, module count, cells per module, voltage level, Ah capacity Ferroamp, Pylon HV, Solxpow (module count also Solax) Override what is reported to the inverter, 0 keeps the default
Reported battery type Solax See Solax battery type information
FoxESS battery type, subtype, module count FoxESS Override what is reported to the inverter, 0 keeps the default
Battery model Sungrow See Sungrow SBRXXX protocol
Inverter Contactor Workaround Kostal, Solax See Notes on CAN controlled contactors

The following options apply to all inverters:

Ramp up charge limits gradually smooths sudden increases in the battery's charge and discharge power limits before sending them to the inverter to prevent oscillation, using a low pass filter in the software. An increase closes 10% of the remaining gap every second, a time constant of about 10 seconds, while a decrease is passed on immediately.

Charge power tapering based on SOC gradually reduces the allowed charge power when approaching the top of the SOC window, from full allowed power down to 0 W at 100% SOC, for a smooth approach to full instead of an abrupt cutoff. It works on the SOC the inverter sees, so it follows Rescale SOC when that is active. It has two settings:

  • Start tapering at SOC, percent (50-99, default 95): the (scaled) SOC where charge power tapering begins.
  • Float charge power, W (0-2000, default 400): the minimum charge power held during tapering until 100% SOC is reached. Recommended to set it to 5-10% of the inverter's max power for a single battery (for double and triple, you can increase the value accordingly). 0 disables this, tapering will go linearly to 0 W. It is never applied when the battery or the safety layer itself allows no charging.

The log shows a line when tapering engages. Both options can be used on their own or together. With a double or triple battery setup, both work on the combined limits of all packs, after parallel headroom tracking has raised the charge limit.

IMPORTANT

Remember to set Max charge current and Max discharge current correctly to match your setup for these options to work properly! Both options start from the power these limits allow.

NOTE

For certain battery integrations tapering is mandatory: the checkbox is shown ticked and greyed out, and the start SOC is limited to 50-85%.

Allow longer CAN timeout: an inverter communicating over CAN is reported missing after 60 seconds without messages from it. This option triples the timeout to 180 seconds, for inverters that are slow to start up.

Inverter run entirely offgrid: when the inverter is missing, an error event is normally raised, which stops the battery from starting. With this option enabled, that event is raised as a warning instead, for installations where the inverter is not connected to the grid.

Optional components config~

Setting Description
Charger and Charger interface An optional HV charger controlled by the Emulator. See Chargers and Charger settings. Not available on the small flash boards.
Measurement and Interface An optional current measurement device: a BMW SBox, the QNHCK2-16 DC current clamp, the CT clamp of a CHAdeMO setup (Custom Clamp), or the current measured by the inverter (Using inverter values, only for the BYD CAN inverter protocol). Only the types usable with the selected battery and inverter are listed.

Hardware config~

Setting Description
Equipment stop button The type of the optional equipment stop button. See Equipment stop.
Contactor control via GPIO, Precharge time ms, Use Normally Closed logic See Contactor control via GPIO
2ⁿᵈ / 3ʳᵈ battery contactor control via GPIO See Double battery
PWM contactor control, PWM Frequency Hz, PWM Hold See PWM control
Periodic BMS Power reset, Every, Defer reset if SOC less than 15%, Skip reset for one period if balancing See Periodic BMS Power reset
External precharge via HIA4V1 and its options See External precharge
Measure CPU temperature, CPU temperature calibration offset (°C) Shows the CPU temperature on the main page. The reading of the internal sensor can be corrected with an offset, measured with a separate thermometer.
Status LED pattern How the status LED animates: Classic pulses steadily, Energy Flow pulses differently while charging, discharging or idle, Heartbeat beats faster on a warning or an error. The LilyGo T-2CAN also offers GRB versions, for LEDs with a different colour order.
Board specific pin options Configurable port on the LilyGo T-2CAN, BMS Power pin, SMA enable pin and µSD Slot on the LilyGo T-CAN485, BMS Power pin on the Stark CMR, GPIO 1/2 function on the Waveshare. See the page of your board.

Integration settings~

Setting Description
Start ESPNow at boot, ESPNow receiver MACs See ESPNow
Enable MQTT and its options See MQTT
Allow remote BMS Power reset See Periodic BMS Power reset
Home Assistant autodiscovery and its options See Home Assistant Discovery

Debug options~

Performance profiling on main page shows detailed performance metrics on the main page. Only needed when asked by developers.

The other options control where the logs go. Battery Emulator keeps two independent log streams: general logging (human-readable status/debug text) and CAN message logging (the raw bus traffic, see CAN logging). General logging can be sent to the webserver Log page, to USB serial, to an SD card and to a remote syslog server, while CAN message logging can be written to USB serial or to an SD card. The webserver and USB serial general logging exclude each other: ticking one unticks the other. Every general log line sent to the webserver, USB or SD card is prefixed with the uptime (seconds.milliseconds).

NOTE

Logging is entirely optional and off by default. Enable only the destinations you actually need — each one adds processing overhead, and USB serial in particular is best left off during normal operation. Like the other settings, they take effect after a reboot.

USB serial~

General logging via USB serial and CAN message logging via USB serial stream the log live over the USB cable. Open a serial terminal on the connected computer at 115200 baud to watch it in real time. This is the quickest way to see what the board is doing during bring-up, but it is also the heaviest option.

WARNING

USB serial logging causes performance issues and should be avoided if possible — especially CAN message logging, which prints every incoming and outgoing frame.

SD card~

On the boards with a µSD slot (LilyGo T-CAN485 and DFRobot Edge101), General logging to SD card and CAN message logging to SD card persist the logs across reboots. Entries are buffered in RAM and written to two files in the card root: general logging to /log.txt and CAN traffic to /canlog.txt. You can download or delete these files from the browser: the general log with the Export to .txt and Delete log file buttons of the Log page, and the CAN log with the Export SD card CAN log and Delete SD card CAN log buttons of the CAN tools page. Because it survives power cycles, SD logging is the best option for catching an intermittent fault that only shows up after hours of running.

NOTE

On the LilyGo T-CAN485, the µSD Slot setting in Hardware config must be set to µSD Card (the default). CAN-to-SD logging is high-volume and adds load, so enable it only while actively troubleshooting.

Remote syslog~

General logging to syslog server forwards each general log line as a UDP syslog datagram in RFC 5424 format to a server of your choice — handy for aggregating logs from a permanently installed system into an existing logging/monitoring setup. Configure the Syslog server (IP address or hostname), the Syslog UDP port (default 514) and the Syslog facility (0–23, default 1 = user).

Each line is tagged with a syslog severity: lines that originate from an event carry that event's level (error → err, warning → warning, firmware update → notice, info → info), milestones such as detecting the battery or the inverter, MQTT connecting or disconnecting, Wi-Fi getting an IP address or disconnecting, BMS resets and the reason of the last reset are raised to notice, and all other lines are sent as debug unless the firmware marks them otherwise. The datagram carries the board's hostname, and as APP-NAME the task of the firmware that produced the line. The timestamp field is left empty (NILVALUE -), so the receiving syslog server stamps each message on arrival.

Datagrams are sent while the board is connected to the home network, or while a device is connected to its access point. Lines logged before that, for example during boot or while the network connection briefly drops, are kept in a 4 KB backlog and sent in a batch once the connection is up, each prefixed with the uptime it was logged at ([boot +12.345s]). If the backlog fills up, the earliest lines are kept and a warning reports how many lines were dropped.

TIP

If you own a Synology NAS, in the Log Center set up a Log Receiving entry in IETF format.

CAN logging~

See the page about CAN logging for more information about the CAN logging function.

Battery limits and actions~

image

These values are changed with their Edit button, which asks for the new value. They are stored and take effect immediately, no saving or reboot is needed. The ⓘ icons explain them on the page.

Battery capacity~

How much energy can your battery store? Some batteries autodetect this via CAN communication, this setting is invisible for them, but for battery types that do not, it is good to manually define the value (1-400000 Wh, default 30000) so that your inverter knows how large the battery is.

Rescale SOC~

If enabled, the system rescales the SOC% between the configured SOC min percentage (-10 to 50, default 20) and SOC max percentage (50 to 100, default 80): the inverter sees 0% when the real SOC reaches the minimum, and 100% when it reaches the maximum. By not using the entire battery, the amount of cycles the battery can last increases. Good practice is to use this feature, and restrict SOC% between 20-80%, however, scaling SOC max too low may cause oscillations when charge approaches the scaled 100%. If you run into this, enable Ramp up charge limits gradually in Inverter config and raise SOC max percentage to 100%.

image

For double and triple setups SOC scaling is applied once, to the installation aggregated total, per-pack values remain unchanged. The scaling can also be changed through MQTT.

Chemistry

For some battery chemistries (LFP especially), rescaling SOC% prevents the battery from top-balancing properly. For these chemistries it is recommended to rescale only the bottom section with SOC min percentage (e.g. using 20-100%).

For batteries of NMC chemistries it's specifically advised against habitual full charging, which adds wear - thus, for longer lifetime, you should set SOC max percentage to around 80 on long term (during the summer, when the pack charges to full quickly, and then stays full almost all day).

Negative rescaling

It is also possible to do negative rescaling, as some inverters restrict the possibility to use the entire battery capacity at the bottom section. With this trick you can circumvent that. Use with caution!

Max charge/discharge current~

  • Max charge current (A)
  • Max discharge current (A)

These settings cap the current that can go in/out of the battery (0-1000 A). Even though most EV packs can push out hundreds of ampere, most inverters will not handle so large amounts of current. Some inverters even stop functioning in case they see allowed a large value. By default this is set to 30 A on charge and discharge. Set this value to correspond to the parameters of your inverter (Inverter Power / Vmin), the wiring or the fuses in your system (whichever the lowest). It is important for these numbers to be correct, in order for the filter and the taper to operate correctly. When this setting is what limits the current, the main page shows (Manual) next to the limit.

image

Example

If you have a 3 kW inverter, the max charge/discharge current would be 3000 W / 300 Vmin = 10 A

Manual charge voltage limits~

Disabled by default. This option can be enabled to manually limit the min/max voltage in the system, with Target charge voltage (default 450.0 V) and Target discharge voltage (default 300.0 V). Note that not all inverters are compatible with voltage based limits, the setting was primarily developed for BYD CAN (see for example Deye). If left disabled, the system will automatically use the entire voltage range of your battery (unless Rescale SOC is enabled).

image

Periodic BMS Power reset~

Periodic BMS Power reset OFF time (1-600 s, default 30) sets how long the BMS stays powered off during a reset, and Perform a BMS Power reset now starts a reset on demand. Both are shown when Periodic BMS Power reset or Allow remote BMS Power reset is enabled. See the dedicated page for Periodic BMS Power reset.

Undercharged emergency recovery mode~

See the dedicated page for Recovering undercharged battery.

Manual LFP balancing~

Only shown for the Tesla Model 3/Y and Model S/X integrations: when enabled, forces a top charge for at most Balancing max time, at Balancing float power, with temporarily raised limits for the pack voltage, cell voltage and cell deviation, to help keep LFP batteries balanced. It is meant to be done about once a month, with the battery fully charged first. See Periodic forced charge-balancing.

Charger settings~

Only shown when a charger is configured: Charger HVDC Enabled and Charger Aux12VDC Enabled switch the high voltage and the 12 V outputs of the charger on and off, while Charger Voltage Setpoint and Charger Current Setpoint set its charging target. The setpoints are checked against the limits of the charger.

More battery info~

The More Battery/Cell Info button of the main page opens a page with detailed information about the battery that is specific to the battery integration: its current status, health and lifetime usage, as the battery reports them. See the page of your battery for what is shown. The page does not refresh itself; reload it to see new values. With a double or triple battery setup, tabs at the top select the battery.

Some battery packs show the stored Diagnostic Trouble Codes, which are read on demand with Read DTC, and can be cleared with Erase DTC. Each code is shown with its status (Active, Confirmed or Stored) and a description, fetched from GitHub (boards with enough flash also carry the descriptions built in).

Depending on what the battery supports, buttons below the information offer battery commands, for example clearing an isolation fault, resetting or calibrating the SOC, resetting the BMS or its degradation data, starting or stopping balancing, or opening and closing the contactors. Commands that change something in the battery ask for a confirmation before they are sent.

The Cellmonitor button opens the Cellmonitor page, showing the same battery.

Cellmonitor~

The Cellmonitor visualizes all the cells in your battery. At the top there is a quick readout of the lowest and highest cell voltage (Min/Max) and the difference between them (Delta). The graph gives a quick visualization of how balanced the battery is, with a grid view of all cells and their values below it. The cells that are lowest and highest are highlighted with a red border for quicker identification of where they are, and cells below 3000 mV are written in red.

image

Click or tap a bar or a cell to select it: its number and voltage are shown above the graph. On a touch screen you can slide your finger along the graph to scrub through the cells. The page refreshes the values every 20 seconds and keeps the selection. With a double or triple battery setup, tabs at the top select the battery.

Interpreting the values~

In general, the lower the voltage deviation in mV, the better. A battery with 10 mV deviation is considerably healthier than one with 100 mV deviation. Individual cells that are lower than the rest can be a sign of early stages of cell failures/degradation/overheating, however, this depends heavily on the chemistry of the battery. Some chemistries like LMO can have way larger deviations at lower SOC% compared to NCM chemistries.

Deviations can also grow under heavy load. If you pull higher power out of the battery, the mV deviation usually increases. This is completely normal.

The system will automatically go into a warning state in case a cell voltage goes too high or too low. The value is battery-specific. If this happens, an event will be raised (see the Events page), and further charging/discharging will be halted.

Balancing status~

On some battery types (like Nissan LEAF, Renault Zoe Gen1 and Gen2, Pylon, Fake battery) we visualize the balancing status that the BMS reports for each cell. Cells that are balancing are shown as cyan bars, and (balancing) is added to the readout of a selected balancing cell. The legend below the graph says Balancing, or Pending while the BMS has flagged the cells for measurement. If the battery reports that balancing is active, the legend says Balancing is active now!, and (balancing now!) is added to the Delta at the top.

CAN tools~

The CAN tools page contains two tools for reverse engineering and troubleshooting:

Log~

When General logging via Webserver or General logging to SD card was enabled at boot (see Debug options), a Log button appears on the main page. With logging via Webserver, this page shows the latest general log lines from the emulator, kept in a buffer of about 15 kB in RAM: the oldest lines are dropped as new ones arrive, and the log starts empty at every boot. The page has these buttons:

  • Refresh data: reloads the page with the latest lines (only with logging via Webserver)
  • Export to .txt: downloads the log as a file. With SD card logging enabled, this downloads the /log.txt file from the SD card instead.
  • Delete log file: deletes the /log.txt file from the SD card (only with SD card logging)
  • Back to main page

NOTE

Logging adds overhead. Webserver and SD-card logging are fine for troubleshooting, but USB-serial logging in particular can cause performance issues and should be left off during normal operation.

Events~

At the bottom of the main page, clicking the Events button will show information about events that have occurred while the system has been running. Each event is shown with its name (Event Type), its Severity, the time it occurred last (Last Event, in your browser's local time), an occurrence counter (Count) so you know if many events of the same type have triggered, an additional value (Data, for example an error code or which battery it relates to), and a Message describing it. The list is ordered with the newest events on top, and refreshes itself every 5 seconds when something changes.

image

The list shows every event that has occurred since the board booted, including the ones whose condition has passed in the meantime. The colour of the main page and of the status LED shows only the events that are still active. Clear all events empties the list: events whose condition is still present are raised again.

The events are grouped into these severities:

Severity Colour Meaning
INFO 🟩 Green Useful information like when the battery has been charged full, completely discharged, reset reason etc. Having info events present does not warrant any user action.
WARNING 🟨 Orange Information that users might want to act upon. The system will try to mitigate certain warnings, like in case the battery is reaching too high voltage, the system will raise a warning event and prevent further charging (only discharging will be possible). Warning events should be analyzed when spotted. The main page, plus the LED on the board, will also turn yellow while a warning event is active.
ERROR 🟥 Red Information about why the system has stopped operation. In case it is no longer safe to continue using the battery, an error event will be generated and charging/discharging is set to 0 W allowed. Check the error event description for information on how to proceed or what to check. The main page, plus the LED on the board, will also turn red while an error event is active.
UPDATE No colour A firmware update is in progress. The main page, plus the LED on the board, turns blue meanwhile.
DEBUG No colour Information for developers

The events are also published through MQTT, and sent to syslog when it is enabled.

OTA update~

The Perform OTA update button opens the page for updating the firmware over-the-air. It shows the hardware and the firmware version the board is running. Charging and discharging are paused during the update. If the upload makes no progress for 15 seconds, a timeout event is raised and charging and discharging resume. See the page OTA Update for more info how.

CAUTION

Working with high voltage is dangerous. Always follow local laws and regulations regarding high voltage work. If you are unsure about the rules in your country, consult a licensed electrician for more information.